| Power | 12 VDC @ 250 ma max. |
| Inputs |
1 normally open momentary (1 sec max) entry access granted relay from
access control system. 1 normally open momentary (1 sec max) exit access granted relay from access control system. Required only for card in / card out systems. Not required for card in / free exit system. 1 normally open maintained system bypass. IRISYS ceiling mounted pedestrian counting sensor |
| Outputs |
1 DPDT lock output relay rated @ 8 AMP 1 normally closed Alarm Relay Alarm sounder @ 85dB Green LED indicates entry access enabled Red LED indicates secured mode - entry will generate an alarm |
| Time Delays |
Access time fixed at 7 seconds. System resets 7 seconds after access is
granted if no passage through sensing area is detected. Alarm automatic reset fixed at 4 seconds. System resets 4 seconds after a count or tailgate alarm is detected. Optional Door Held Open Warning fixed at 20 seconds. System will generate local warning alarm if door is held open for 20 seconds after the last valid passage is detected. Optional Door Held Open Alarm fixed at 20 seconds. System will generate a door held alarm if door is held open 20 seconds past the start of the warning delay. |
| Field Adjustments | Tailgate Sensitivity and sensing area adjustment using sensor setup software via RS232 serial port and PC with Windows 2000 or XP. |
| Mounting |
Ceiling mounted sensor is placed above doorway looking down at passage
area. LDA circuit board is mounted next to the card reader interface module, either in a makeup box or in the equipment room where the card reader system is located. Sounder and LED Trim Plate may be mounted at the door mullion, 1 gang box near the door, or in the ceiling above the door. |
| Dimensions |
LDA circuit board module – 10.5” x 10.5” sub-plate fits in 12” x 12”
enclosure. Ceiling Mounted Sensor Housing - 4.4” diameter x 2” deep Sensing area – 7’6” x 7’6” @ 8’ ceiling height Display plate – single gang electrical box Display plate with integrated industry standard proximity card reader – double gang electrical box |
![]() ![]() |